    Digital pH/ORP Wall Mounted System

    • bvseo_sdk, java_sdk, bvseo-3.1.0
    • CLOUD, getAggregateRating, 115ms
    • REVIEWS, PRODUCT
    • bvseo-msg: The resource to the URL or file is currently unavailable.;
    Item # E6260
    $1,925.99

      Digital ORP/pH Controller Wall System

      This unit includes a programmable digital ORP/pH controller complete with a flow cell, flow switch and sample valves. Also comes equipped with ORP and pH probes, 40 ft. of Black 3/8 in. tubing, 100 ft. Clear 7/16 in. tubing and fittings and two peristaltic pumps (32GPD). System comes mounted on a Polypropylene Board for complete convenience. NSF50 Approved.

      This system will monitor and maintain the pH balance and sanitizer level in a swimming pool or spa.

      NOTE: This system is designed to control pools up to 100,000 gallons. Larger pools may require larger GPD peristaltic pumps.

      • Customer Review
      • TROUBLESHOOTING
      • MORE INFO
      • bvseo_sdk, java_sdk, bvseo-3.1.0
      • CLOUD, getReviews, 0ms
      • REVIEWS, PRODUCT
      • bvseo-msg: The resource to the URL or file is currently unavailable.;

      Chemicals not feeding?

      • Flow light on Controller must be illuminated. Check flow switch (manifold) if light is not on (section 3.3.3).
      • Feeder power and time switches must be in ‘ON’ position. Check feeder by using alternate power source.
      • Factory setting for feed time is 0.6 sec on with 5 minute delay. Feeders may require longer feed time. 

      Displayed chemical level doesn’t correspond to actual?

      • ORP=0, pH=6.8 indicates sensors (probe) are attached to incorrect connector.
      • Sensors (probe) need cleaning.
      • Sensors (probe) need replacing.
      • Note: OPR probe reading can be affected by pH probe. Both probes must be in good operating condition.

      Set-points not being reached /maintained?

      • Factory setting for feed time is 0.6 sec on with 5 minute delay. Feeders may require longer feed time. If time is too short, set-points will not be maintained. If time is too long, overfeeding chemicals will occur. Correct time is dependent of multiple factors such as pool / spa water volume, feeder output, chemical concentration and chemical needs.
      • Controllers are designed to maintain set-points. Do not expect Controllers to make major adjustments-major changes should be done manually.
      • Pump/feeders must be large enough to reach desired set-points in a relatively short time. Automation using controllers may require larger feeder or more concentrated chemicals than system that uses continuous time controlled feeding (i.e. feeders only).

      For additional trouble shooting contact manufacture Rola-Chem at 800-549-4473 Mon-Fri 8am-5pm Central Time.