Technical Specifications:

  • Patented Turbo Cell for maximum efficiency and flow rate
  • UL and CUL listed
  • 5 year limited warranty (see manual for complete details)
  • Quick and easy 30 minute installation
  • The best water quality attainable -- always crystal clear and ready for swimming
  • Soft silky feel -- no more red eyes or dry skin
  • Digital salt display and 7 diagnostic indicators
  • Selectable super chlorinate function
  • 24 hour timer for the filter pump control allows multiple pump periods per day
  • Capable of programming in 15 minute increments
  • Manual switch (ON-Auto-OFF)
  • Microprocessor automates all functions
  • Automatically cleans the cell by periodically reversing polarity
  • Automatically cleans the cell by periodically reversing polarity


  • Back To The Top

    Frequently Asked Questions:

    Why is my “power” LED not lit?
    – Check to make sure 120V AC input power is connected to the Aqua Trol control. Verify input voltage with a voltmeter. If there is input power, the fuse may have blown. The unit is protected by a 20 amp mini ATO fuse located on the circuit board above the cell connector.

    Why is my “generating” LED not lit?
    – The Aqua Trol only generates chlorine when the filter pump is running, the main switch is in the “Auto” or “Super Chlorinate” position, and none of the red fault LEDs are illuminated.

    Why is my “generating” LED flashing?
    – The temperature of the pool water is too high or low to operate. You can override this by switching the main switch to “Super Chlorinate.” The Aqua Trol will run at maximum output for the remainder of the current pump cycle or 24 hours, whichever comes first.

    Why is the “No Flow” LED lit?
    – The Aqua Trol has sensed a no flow condition and has stopped generating chlorine. Check that the flow switch is plugged into the connector on the bottom of the control unit and that the wire is not cut or damaged. Make sure you have at least 12” of straight pipe before the flow switch. If there is adequate flow and the LED is still on, check that the arrows on the flow switch (on top of hex) are pointing in the direction of flow.

    Why is the “Test Salt Level” LED lit or flashing?
    – Take a sample of your pool water to your local pool store and have the salt level tested. No salt test is completely accurate and the test results may vary from the salt level on the Aqua Trol display. If salt level is low, add salt according to the chart in the owner’s manual.

    Why is the “High Salt” LED lit?
    – Check the salt level in the pool. If it is too high, lower the salt level by draining some of the pool water out of the pool and replace with fresh water.

    Why is the “Inspect Cell” LED flashing?
    – Inspect and clean the cell according to manufacturer directions. When done, press the “diagnostic” button for 3 seconds to stop the flashing.

    WWhy is the “Inspect Cell” LED lit?
    – Remove and inspect the cell for scale. If the cell is scaled, clean per manufacturer directions. If the pool has the proper amount of salt and the “Inspect Cell” LED is still lit, the cell may be worn and need replacement.

    Why am I getting little or no free chlorine residual?
    – Aqua Trol switch in the “off” position.
    – The desired level % adjustment setting is too low.
    – Low stabilizer level.
    – Filter pump switched off or filter pump time too short (8 hours for average size pools, more for large pools).
    – Salt level too low (below 2500 ppm)
    – Salt level too high (High Salt LED lit).
    – Pool water warmer than usual, increase “desired level %” or run filter longer.
    – If water temperature falls below 50 degrees F, the Aqua Trol stops generating.
    – Excessive scaling on the cell.
    – High level of Nitrogen in pool water.
    – Yellow algae treatments (Yellow Out) use chlorine at a high rate and deplete the residual free chlorine.


    Why is “-Pcb-” displayed and all 4 red/yellow LEDs lit?
    – There is a possible Printed Circuit Board fault. Call the manufacturer for service (888-921-POOL).


    Back To The Top



    Related Items
      Click to enlarge image


         Product 1 out of 5 in Above Ground Salt Chlorine Generators  Next »   


    Shop the Best Brands in the Pool Business! Visit Our Superstore Pages Below.



     

      SIGN UP FOR WEEKLY EMAIL PROMOTIONS  

    Customer Service
    · Measuring Forms
    · Water Testing
    · FAQs
    · Contact Us

    Shopping
    · My Account
    · Shipping & Tax
    · Returns & Exchanges
    · Order Tracking

     

    Company
    · About Us
    · Employment
    · Privacy & Security
     Catalog
    · Request a Catalog
    · Place a Quick Order

    In The Swim, Swimming Pool Equipment & Supplies, West Chicago, IL
    HACKER SAFE certified sites prevent over 99% of hacker crime.
    In The Swim- America's #1 Direct Source For Pool Supplies

    In The Swim®
    320 Industrial Drive
    West Chicago, IL 60185
    1-800-288-7946